■ INTRODUCTION
CO₂purifier EGS33 operates with a catalytic bed connected in series to adsorption beds.The catalytic bed works at elevated temperatures without the need for regeneration,while multiple adsorption beds connected n parallel alternate between ambient temperature purification and high-temperature regeneration modes,with service life over 20 years.
■ INDEX TABLE
适 用 气 体 A P P L I C A B L E G A S | CO₂ | |
型 号 M O D E L | EGS32 | EGS33 |
工 艺 C R A F T S | ADS | CAT+ADS |
杂质IMPURITY | OUTLET | OUTLET |
ppb | ppb | |
H₂O | <1 | <1 |
O₂ | <1 | <1 |
Co | <1 | <1 |
H₂ | <1 | <1 |
CH₄ | 一 | <1 |
Total Volatile Acids(as SO2) | <0.005 | <0.005 |
Total Volatile Bases(as NH3) | <0.5 | <0.5 |
Condensable Organics(HCS>100 amu,as Decane) | <0.15 | <0.15 |
Non-Condensable Organics(HCS>58 amu,as Toluene) | <1 | <1 |
Refractonies(as HMDSO) | <0.005 | <0.005 |
PARTICLES | ≤1pcs/m³(@0.003μm) | |
流量范围 | 10-700Nm³h | |
▶Note:Only the specification and configuration of the standard models are listed in the table.Please contact EGP for more special requirements.